Skip to main content
5 events
when toggle format what by license comment
Jul 30, 2022 at 2:14 comment added David White I suspect that you are doing a hydrotest of a vessel to verify vessel integrity. Is there a maximum "leak rate" that is tolerable? In other words, given the fact that small temperature variations will cause various differential expansion or contraction of equipment and fluid, it's probably not reasonable to expect absolutely zero change in pressure over time.
Jul 29, 2022 at 21:19 answer added RC_23 timeline score: 0
Jul 29, 2022 at 21:11 history edited JSRambal CC BY-SA 4.0
added 83 characters in body
S Jul 29, 2022 at 21:07 review First questions
Jul 29, 2022 at 22:24
S Jul 29, 2022 at 21:07 history asked JSRambal CC BY-SA 4.0