Timeline for breakdown voltage in vacuum
Current License: CC BY-SA 3.0
4 events
when toggle format | what | by | license | comment | |
---|---|---|---|---|---|
May 26, 2017 at 20:46 | vote | accept | Saesun Kim | ||
May 26, 2017 at 20:32 | answer | added | Floris | timeline score: 4 | |
May 26, 2017 at 20:23 | comment | added | Jon Custer | What you would get by extrapolating from Paschen curves is probably not very useful for estimating the real breakdown. Instead of being a gas/volume question, it will be a surface finish and surface contamination question. This makes it almost impossible to come up with an analytical solution. You may need in situ plasma cleaning and/or conditioning runs to get maximum breakdown voltages. | |
May 26, 2017 at 20:14 | history | asked | Saesun Kim | CC BY-SA 3.0 |